Key takeaways
- For swing gates, the chart's maximum weight and maximum length are separate figures: the CSW24UL product guide gives 1,600 lbs. at 8 ft. but 600 lbs. at 18 ft.
- For three models, LiftMaster's installation manuals list fewer usage classes than its product guides do; the usage class section names them.
- The chart lists battery backup from 20 to 500 cycles for ten models, no battery backup figure for the two AC-powered models, and solar power as standard for one linear actuator.
- The CSL24UL manual says: "A minimum of two independent monitored entrapment protection devices are required to be installed at each entrapment zone."
- The KPW250 wireless keypad holds up to 250 permanent four-digit PINs and the KPW5 up to 5. This page does not reproduce programming steps or codes.
Identify
Which LiftMaster gate operator do I have?
LiftMaster's feature chart lists seven swing operators, three of them linear actuators, and six slide operators. The table gives each one's chart description, maximum gate weight, maximum gate length and recommended cycles.
The chart's fourteenth model, described there as a specialty overhead operator, is not covered here. LiftMaster's gate operators category page also lists the MA, MAS, MAT, MAST and other models this page does not cover. For how readers, keypads and controllers fit together at a door or gate, see how commercial access control works.
For the 1 HP SL3000UL, the product page headline, the chart and the installation manual give 2,000 lbs., while a second tile on the same product page reads "1 HP Rated for gates up to 50 feet in length and 1,500 lbs."
| Model | Type | Chart description | Max. gate weight | Max. gate length | Recommended cycles |
|---|---|---|---|---|---|
| LA400PKGUL (product page: LA400UL) | Swing | 24VDC Linear Actuator | 850 lbs. | 16 ft. | 100 cycles |
| LA412PKGUL (product page: LA412UL) | Swing | 12VDC Solar Linear Actuator | 850 lbs. | 16 ft. | 100 cycles |
| LA500PKGUL (product page: LA500UL) | Swing | 24VDC Residential/Light Commercial Linear Actuator | 1600 lbs. | 18 ft. | 300 cycles |
| RSW12UL | Swing | 12VDC Residential/Light Commercial Swing Gate Operator | 1000 lbs. | 16 ft. | 250 cycles |
| CSW24UL | Swing | 24VDC High-Traffic Commercial Swing Gate Operator | 1600 lbs. | 18 ft. | Continuous Duty |
| CSW200UL | Swing | AC Commercial High-Traffic Swing Gate Operator | 1/2 HP 1600 lbs.; 1 HP 2000 lbs. | 1/2 HP 18 ft.; 1 HP 22 ft. | Continuous Duty |
| HDSW24UL | Swing | 24VDC Heavy Duty Commercial Swing Gate Operator | 2800 lbs./4500 lbs. w/optional arm (HDLGARM) | 22 ft. @ 2500 lbs.; 14 ft. @ 4500 lbs. | Continuous Duty |
| RSL12UL | Slide | 12VDC Residential/Light Commercial Slide Gate Operator | 800 lbs. | 25 ft. [manual: gate travel distance minimum 25 feet, maximum 50 feet] | 120 cycles |
| CSL24UL | Slide | 24VDC High-Traffic Commercial Slide Gate Operator | 1500 lbs. | 50 ft. | Continuous Duty |
| SL3000UL | Slide | AC Commercial High-Traffic Slide Gate Operator | 1/2 HP 1000 lbs.; 1 HP 2000 lbs. | 1/2 HP 50 ft.; 1 HP 50 ft. [manual: maximum gate travel distance 52 feet] | Continuous Duty |
| HDSL24UL | Slide | 24VDC Heavy Duty Commercial Slide Gate Operator | 3000 lbs. | 75 ft. | Continuous Duty [manual: "Continuous for line voltage, not continuous for solar"] |
| INSL24UL | Slide | 24VDC Slide Gate Operator | 2200 lbs. | 70 ft. | Continuous Duty [manual: "Continuous for line voltage, not continuous for solar"] |
| IHSL24UL | Slide | 24VDC Slide Gate Operator | 5500 lbs. | 90 ft. | Continuous Duty [manual: "Continuous for line voltage, not continuous for solar"] |
Source LiftMaster's UL 325 Listed Gate Operator Feature Chart (11/22), its product pages and gate operators category page as read on 10 November 2026, and the SL3000UL, RSL12UL, HDSL24UL and IHSL24UL, INSL24UL installation manuals.
Swing gates
Will it move my swing gate?
On a swing gate, the weight an operator can move falls as the gate gets longer. The chart gives each swing operator one maximum weight and one maximum length, and the CSW24UL product page words it as "Rated For gates up to 18ft. or 1,600 lbs." The product guides and installation manuals give a weight for each gate length; the table shows both as printed.

| Model | Product guide | Installation manual |
|---|---|---|
| LA400PKGUL | 850 lbs. at 10 ft.; 750 lbs. at 12 ft.; 650 lbs. at 14 ft.; 550 lbs. at 16 ft. | 850 lbs. / 10 ft; 750 lbs. / 12 ft; 650 lbs. / 14 ft; 550 lbs. / 16 ft |
| LA412PKGUL | 850 lbs. at 10 ft.; 750 lbs. at 12 ft.; 650 lbs. at 14 ft.; 550 lbs. at 16 ft. | Not listed |
| LA500PKGUL | 1,600 lbs. at 8 ft.; 1,200 lbs. at 12 ft.; 800 lbs. at 16 ft.; 600 lbs. at 18 ft. | 1600 lbs. / 8 ft; 800 lbs. / 16 ft; 600 lbs. / 18 ft |
| RSW12UL | 1,000 lbs. at 6 ft.; 700 lbs. at 10 ft.; 400 lbs. at 16 ft. | 1000 lbs. / 6 ft.; 800 lbs. / 8 ft.; 700 lbs. / 10 ft.; 600 lbs. / 12 ft.; 400 lbs. / 16 ft. |
| CSW24UL | 1,600 lbs. at 8 ft.; 800 lbs. at 16 ft.; 600 lbs. at 18 ft. | 1200 lbs. / 12 foot; 800 lbs. / 16 foot; 600 lbs. / 18 foot |
| CSW200UL, 1/2 HP (CSW200501UL) | 1,600 lbs. at 8 ft.; 1,200 lbs. at 12 ft.; 800 lbs. at 16 ft.; 600 lbs. at 18 ft. | 600 lbs., 20 feet |
| CSW200UL, 1 HP (CSW200101UL) | 2,000 lbs. at 12 ft.; 1,600 lbs. at 16 ft.; 1,400 lbs. at 18 ft.; 1,000 lbs. at 22 ft. | 1000 lbs., 22 feet |
| HDSW24UL, standard arm | 2,800 lbs. at 14 ft.; 2,200 lbs. at 18 ft.; 1,500 lbs. at 22 ft. | 14 ft. - 2,800 lbs.; 16 ft. - 2,400 lbs.; 18 ft. - 2,200 lbs.; 20 ft. - 1,800 lbs.; 22 ft. - 1,500 lbs. |
| HDSW24UL, long arm | 4,500 lbs. at 14 ft.; 3,750 lbs. at 16 ft.; 3,250 lbs. at 18 ft.; 2,750 lbs. at 20 ft.; 2,500 lbs. at 22 ft. | 14 ft. - 4,500 lbs.; 16 ft. - 3,750 lbs.; 18 ft. - 3,250 lbs.; 20 ft. - 2,750 lbs.; 22 ft. - 2,500 lbs. |
Source The feature chart, the CSW24UL product page, and the product guide and installation manual for each swing model.
Usage class
Which usage class is it listed for?
The CSL24UL installation manual defines four usage classes. Class I is "intended for use in garages or parking areas associated with a residence of one-to four single families." Class II is "intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other buildings accessible by or servicing the general public."
The two documents differ for three models: the LA400 manual lists Class I, II, & III, and the RSW12UL and RSL12UL manuals list Class I & II, while the 12/21 product guides for all three list I, II, III and IV.
| Model | Installation manual | Product guide |
|---|---|---|
| LA400PKGUL | Class I, II, & III | I, II, III and IV |
| LA412PKGUL | Not listed | I, II, III and IV |
| LA500PKGUL | Class I, II, III, & IV | I, II, III and IV |
| RSW12UL | Class I & II | I, II, III and IV |
| CSW24UL | Class I, II, III, & IV | I, II, III and IV |
| CSW200UL | Class I, II, III, & IV | I, II, III and IV |
| HDSW24UL | Class I, II, III, & IV | I, II, III and IV |
| RSL12UL | Class I & II | I, II, III and IV |
| CSL24UL | Class I, II, III, & IV | I, II, III and IV |
| SL3000UL | Class I, II, III, & IV | I, II, III and IV |
| HDSL24UL | Class I, II, III, and IV | I, II, III and IV |
| INSL24UL | Class II, III, and IV | II, III and IV |
| IHSL24UL | Class II, III, and IV | II, III and IV |
Source The CSL24UL installation manual's usage class definitions, and the installation manual and 12/21 product guide for each model.
Power
How is it powered?
The chart gives each model's standard power, battery backup cycles and solar cycles per day. Its footnote says cycles marked * are for Zone 1 with a 10W solar panel (6 hours sunlight per day), and cycles marked ** are for Zone 1 with a 20W solar panel.
On batteries, the LA500 manual's accessories list says: "Two identical 12 Vdc batteries are required for each gate operator. Do not mix 7AH and 33AH batteries within a gate operator."
The documents disagree on solar for the two industrial slide models. The chart lists about 20 cycles a day for the INSL24UL with a 20W panel and "Not Recommended" for the IHSL24UL. Their shared product guide, dated 5/22, says "Note: Not recommended for solar applications.", and both models' data sheets, also dated 5/22, list "Solar-Power Capabilities Yes".
The CSL24UL product guide describes two behaviors in LiftMaster's words. Under the heading Fire Department Compliance: "Allows gate to auto-open upon loss of AC power or battery depletion." Under Manual Disconnect: "When unlocked allows gate to be opened manually."
| Model | Standard power | Battery backup | Solar cycles per day |
|---|---|---|---|
| LA400PKGUL | 115V Single Phase [LA400UL data sheet, 12/21: 120/230VAC single phase] | 400 cycles | Approx. 81 cycles* |
| LA412PKGUL | Solar Power | Not Applicable - Solar | Approx. 100 cycles* |
| LA500PKGUL | 115/230V Single Phase | 500 cycles | Approx. 43 cycles* |
| RSW12UL | 115V Single Phase | 147 cycles | Approx. 41 cycles* |
| CSW24UL | 115V/230V Single Phase | 146 cycles | Approx. 16 cycles* |
| CSW200UL | 115V Single Phase | Not listed | Not listed |
| HDSW24UL | 115V/230V Single Phase | 45 cycles | Approx. 14 cycles* |
| RSL12UL | 115V Single Phase | 114 cycles | Approx. 33 cycles* |
| CSL24UL | 115V/230V Single Phase | 208 cycles | Approx. 22 cycles* |
| SL3000UL | 115V Single Phase | Not listed | Not listed |
| HDSL24UL | 115V/230V Single Phase | 45 cycles | Approx. 12 cycles* |
| INSL24UL | 115V/230V Single Phase | 55 cycles [product guide: 55 on 7Ah batteries, 170 on 33Ah] | Approx 20 cycles** |
| IHSL24UL | 115V/230V Single Phase | 20 cycles [product guide: 20 on 7Ah batteries, 60 on 33Ah] | Not Recommended |
Source The feature chart's power rows and footnote, the LA400UL product data sheet, the LA500 installation manual, the IHSL24UL / INSL24UL product guide and data sheets, and the CSL24UL product guide.
Safety
What safety devices does LiftMaster say a gate needs?
LiftMaster's CSW24UL product page says the operator is "Tested to the most stringent UL 325 industry guidelines" and that external entrapment protection devices are needed "to meet UL 325 standards". It adds: "Your Installer will recommend suitable entrapment protection devices for your installation, such as photoelectric or edge sensors."
The CSL24UL manual's cover adds: "This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates." Its requirements read: "A minimum of two independent monitored entrapment protection devices are required to be installed at each entrapment zone." and "It is the responsibility of the installer to install external monitored entrapment protection devices for each entrapment zone." On gate construction it says: "Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction."
The same manual's list for end users includes: "Contact a trained gate systems technician to maintain and repair the gate system (End users should never attempt to repair the gate system)." and "Discontinue use if safety systems operate improperly, the gate is damaged, or the gate is difficult to move."
Two manuals word the direction rule differently. The CSL24UL manual says: "The operator will only operate with a minimum of two independent monitored entrapment protection devices installed in each direction; two in the open direction and two in the closed direction." The LA500 swing manual says: "The operator will only operate with a minimum of two independent monitored entrapment protection devices installed in either the open or closed direction."
The table lists the safety and detection devices LiftMaster's documents name.
| Device | LiftMaster's description | Max. range | Where it appears |
|---|---|---|---|
| LMRRUL monitored retro-reflective photo eye | "enhanced retro-reflective photo eye now with heater and wider beam" | 50 ft. | What's Included on all 13 operator product pages |
| LMTBUL monitored through-beam photo eyes | Monitored through-beam photo eyes | 90 ft. | CSW24UL product guide |
| LMWEKITU monitored wireless edge kit | Low-energy Bluetooth connection between a LiftMaster monitored resistive edge and the gate operator; up to 4 transmitters, 2 resistive edges per transmitter | 130 ft. | CSW24UL product guide |
| S505AL | 5 ft small profile resistive edge with aluminum channel | Not listed | What's Included on the six slide operator product pages |
| LOOPDETLM plug-in loop detector | "Not to be used as entrapment protection." | Not listed | LA500 installation manual |
Source The CSW24UL product page and product guide, the CSL24UL installation manual, the LA500 installation manual, and the What's Included lists on the 13 operators' product pages.
Keypads
The KPW250, KPW5, KPR2000 and SRDRKP keypads
This page covers four LiftMaster keypads: two wireless keypads, a wired keypad and proximity card reader, and the keypad model of LiftMaster's Smart Readers. The table gives each one's capacity, power and connection.

The KPW instructions say the keypads "are security keypads and should be programmed to ONE operator." They have sections headed Basic Programming, Program to Operator and Additional Programming. This page does not reproduce programming steps or codes.
On placement, the instructions state: "User activation controls MUST be located at least 6 feet (1.8 m) away from ANY moving part of the gate and where the user cannot reach over, under, around or through the gate to operate the controls."
For LiftMaster's video intercoms, see Elwin's comparison of DoorKing and LiftMaster telephone entry.
| Keypad | Type | Users or PINs | Power | Range and connection |
|---|---|---|---|---|
| KPW250 | Wireless commercial keypad | Up to 250 permanent 4-digit PINs; up to 10 unique temporary PINs | 9V lithium battery, life up to 5 years (based on 25 activations per day) | Up to 500 feet in an open field; programmable to 1 LiftMaster gate operator or commercial door operator |
| KPW5 | Wireless commercial keypad | Up to 5 permanent 4-digit PINs; up to 10 unique temporary PINs | 9V lithium battery, life up to 5 years (based on 25 activations per day) | Up to 500 feet in an open field; programmable to 1 LiftMaster gate operator or commercial door operator |
| KPR2000 | Wired keypad and proximity reader; product page: "Single-Entry Multi-Function Access Controller With Integrated Keypad And Card Reader" | 2,000 users (card, 4 to 6 digit PIN, or a combination of card and PIN) | 12 to 24 VDC or 12 to 18 VAC | Stand-alone or Wiegand pass-through modes; programmable output relay "appropriate for" a gate operator, commercial door operator, door strike or solenoid lock |
| SRDRKP | 10-key keypad smart reader | Not listed | Not listed | "Mobile BLE; 125 KHz Proximity; 13.56 MHz Smart"; data sheet: connectivity depends on the door controller, CAPXLV2, CAPXM, CAPXS or CAP2D |
Source LiftMaster's KPW250 / KPW5 product guide (01/22) and KPW5, KPW250 instructions, the KPR2000 product page and product guide, and the SRDRST and SRDRKP Smart Readers data sheet (8/23).
Connectivity
Does it work with myQ?
The feature chart's "myQ Enabled" row reads Yes for each of the 13 models. LiftMaster says myQ technology enables you to securely control and monitor your gate operator from anywhere, with the footnote "Cellular data or Wi-Fi connection required. Test equipment regularly and follow safety instructions."
The connection runs through a separate device, the 828LM Internet Gateway, which "connects myQ-enabled gate operators to the Internet and enables control through the myQ App." The LA500 manual marks the gateway as not provided, and the INSL24UL product page says monitoring and control with myQ "requires additional Internet Gateway unit".
Source The feature chart, the CSW24UL and LA400PKGUL product guides, the LA500 installation manual and the INSL24UL product page.
Manuals
Where are the manuals?
Each product page links one English installation manual, except the LA412UL page, which links a wiring diagram and an addendum under Manual instead. The table gives each manual's number and back-cover copyright year and any label the product page puts on it.
The manuals address the installer. The CSL24UL manual runs from safety and installation through adjustment, programming and troubleshooting, with a diagnostic codes table, to a safety checklist, and it says: "DO NOT attempt repair or service of your gate operator unless you are an Authorized Gate Systems Technician." This page does not reproduce the manual's programming and adjustment sections.
The CSW24UL product page also links a troubleshooting guide labelled "Models manufactured after 2022", whose cover reads "TROUBLESHOOTING GUIDE for 2022 UL 325 Compliant Gate Operators". Its cover note on the models it does not include is quoted with the manuals table.
| Model | Manual number | Copyright year | Product page label |
|---|---|---|---|
| LA400UL | 01-39384B | 2018 | None |
| LA412UL | Not listed | Not listed | None |
| LA500PKGUL, LA500DC, LA500DCS | 114-6272-000 (Rev. A) | 2025 | None |
| RSW12UL | 01-39378B | 2018 | "(Manufactured Prior to 2022)" |
| CSW24UL | 01-39380B | 2018 | "(Manufactured Prior to 2022)" |
| CSW200UL | 01-39374B | 2018 | None |
| HDSW24UL | 114-5335-000 | 2020 | "(Manufactured Prior to 2022)" |
| RSL12UL | 01-39379 (Rev. C) | 2023 | None |
| CSL24UL | 01-39381 (Rev. C) | 2023 | None |
| SL3000UL | 01-39375B | 2018 | None |
| HDSL24UL | 114-5331-000E | 2019 | None |
| IHSL24UL, INSL24UL | 114-5573-000C | 2022 | None |
Source The Installation & Support block on each product page as read on 10 November 2026, the back cover of each installation manual, the CSL24UL installation manual, and the UL 325 gate operator troubleshooting guide.
Service
Help with a LiftMaster gate operator or keypad
Elwin Security installs, repairs, replaces and supports LiftMaster gate operators, keypads and gate entry devices through its gate access control systems service for commercial and multifamily properties in the San Francisco Bay Area. Calls are answered 8:00 AM-8:00 PM daily at (408) 539-0535.
FAQ
LiftMaster gate operator questions
Is a LiftMaster gate opener the same as a LiftMaster garage door opener?
LiftMaster's site lists garage door openers and gate operators as separate entries, and this page covers gate operators only.
How heavy a gate can a LiftMaster CSW24UL move?
LiftMaster's feature chart lists 1,600 lbs. and 18 ft. as separate maximums. By gate length, the product guide runs from 1,600 lbs. at 8 ft. to 600 lbs. at 18 ft.; the swing gate table gives every point in the guide and the 2018 manual.
Where are the programming steps for a LiftMaster gate keypad?
LiftMaster's instructions for its two wireless keypads have sections headed Basic Programming, Program to Operator and Additional Programming. This page does not reproduce programming steps or codes.
Sources and further reading
These sources back up the general guidance. Your building and the people who approve the work decide the details for your doors.
- LiftMaster: UL 325 Listed Gate Operator Feature Chart, LMGTCTOOSBMC21 11/22 (2 pages)
- LiftMaster: Model LA400PKGUL Product Guide, LMPAENPGLA400MC21 12/21
- LiftMaster: Model LA412PKGUL Product Guide, LMPAENPGLA412MC21 12/21
- LiftMaster: Model LA500PKGUL Product Guide, LMPAENPGLA500MC21 09/25
- LiftMaster: Model RSW12UL Product Guide, LMPAENPGRSW12MC21 12/21
- LiftMaster: Model RSL12UL Product Guide, LMPAENPGRSLMC21 12/21
- LiftMaster: Model CSW24UL Product Guide, LMPAENPGCSW24MC21 12/21
- LiftMaster: Model CSL24UL Product Guide, LMPAENPGCSL24MC21 12/21
- LiftMaster: Model CSW200UL Product Guide, LMPAENPGCSW200MC21 12/21
- LiftMaster: Model SL3000UL Product Guide, LMPAENPGSL3000MC21 12/21
- LiftMaster: Model HDSW24UL Product Guide, LMPENPGHDSW24MC21 12/21
- LiftMaster: Model HDSL24UL Product Guide, LMPENPGHDSL24MC21 12/21
- LiftMaster: Models IHSL24UL / INSL24UL Product Guide, LMPAENPGIHSL 5/22
- LiftMaster: LA400UL Installation Manual, 01-39384B, copyright 2018
- LiftMaster: LA500PKGUL, LA500DC, LA500DCS Installation Manual, 114-6272-000 (Rev. A), copyright 2025
- LiftMaster: RSW12UL Installation Manual, 01-39378B, copyright 2018
- LiftMaster: RSL12UL Installation Manual, 01-39379 (Rev. C), copyright 2023
- LiftMaster: CSW24UL Installation Manual, 01-39380B, copyright 2018
- LiftMaster: CSL24UL Installation Manual, 01-39381 (Rev. C), copyright 2023
- LiftMaster: CSW200UL Installation Manual, 01-39374B, copyright 2018
- LiftMaster: SL3000UL Installation Manual, 01-39375B, copyright 2018
- LiftMaster: HDSW24UL Installation Manual, 114-5335-000, copyright 2020
- LiftMaster: HDSL24UL Installation Manual, 114-5331-000E, copyright 2019
- LiftMaster: IHSL24UL, INSL24UL Installation Manual, 114-5573-000C, copyright 2022
- LiftMaster: UL 325 Gate Operator Troubleshooting Guide (file 114-5965-000.pdf), copyright 2023
- LiftMaster: LA400UL Product Data Sheet, LMARENDSLA400MC21 12/21
- LiftMaster: INSL24UL Data Sheet, LMARENDSINSL 5/22
- LiftMaster: IHSL24UL Product Data Sheet, LMARENDSIHSL 5/22
- LiftMaster: Models KPW250 / KPW5 Product Guide, LMPAENPGKPWMC21 01/22
- LiftMaster: KPW5, KPW250 Instructions, 114-5687-000, copyright 2022
- LiftMaster: Model KPR2000 Product Guide, LMPAENPGKPR2 0118
- LiftMaster: SRDRST and SRDRKP Smart Readers Data Sheet, LMACENDSSR 8/23
- LiftMaster: Gate operators category page
- LiftMaster: CSW24UL product page
- LiftMaster: CSL24UL product page
- LiftMaster: SL3000UL product page
- LiftMaster: RSL12UL product page
- LiftMaster: RSW12UL product page
- LiftMaster: HDSW24UL product page
- LiftMaster: LA412UL product page
- LiftMaster: INSL24UL product page
- LiftMaster: KPW250 product page
- LiftMaster: KPW5 product page
- LiftMaster: KPR2000 product page
- LiftMaster: SRDRKP product page